1. All 3M Products
  • 3M™ Fire Barrier Cast-In Device Metal Deck Adaptors
  • 3M™ Fire Barrier Cast-In Device Metal Deck Adaptors

    3M ID B40065429
    • Allows for fast, easy cast-in firestop installation on fluted metal decks
    • Designed for use with 3M™ Fire Barrier Cast-In Devices
    • Easy snap-in assembly of Cast-In Devices saves time and requires no fasteners
    • One-piece body attaches easily to metal decking before slabs are poured
     More
    Details
    • Allows for fast, easy cast-in firestop installation on fluted metal decks
    • Designed for use with 3M™ Fire Barrier Cast-In Devices
    • Easy snap-in assembly of Cast-In Devices saves time and requires no fasteners
    • One-piece body attaches easily to metal decking before slabs are poured
    • Used in conjunction with Fire Barrier Cast-In Devices, adaptors are firestop tested for up to 3-hours in accordance with ASTM E 814 (UL 1479)

    3M™ Fire Barrier Cast-In Device Metal Deck Adaptors are one-piece plastic body adaptors for one-step firestopping on fluted metal decks. Installers simply snap a metallic or non-metallic 3M™ Fire Barrier Cast-In Device into the adaptor – no fasteners are required – and attach it to the metal decking before concrete slabs are poured. Adaptor/device assemblies are firestop tested up to 3 hours.

    Simply a Better Way to Firestop
    To expand the versatility of our time- and money-saving cast-in firestopping, our 3M™ Fire Barrier Cast-In Device Metal Deck Adaptors let technicians install our 3M™ Fire Barrier Cast-In Devices onto uneven metal fluted decking before concrete slabs are poured. This one-piece plastic adaptor features snap-in attachment to the Fire Barrier Cast-In Device – no tools or fasteners are required. It installs quickly and easily onto fluted steel pan decks for drain, waste and vented or closed pipe systems. The adaptor accepts Cast-In Devices for both plastic and metal pipes.

    Recommended Applications


    Use in conjunction with metallic and non-metallic 3M™ Fire Barrier Cast-In Devices
    Fluted steel pan decks for drain, waste, and vented or closed pipe systems
    New construction jobs requiring a minimum 2-1/2”(63.5 mm) concrete topping
    Consult 3M™ Fire Barrier Cast-In Device Metal Deck Adaptor Installation Guide (supplied with each device) and listed system details for exact type of penetrants covered and hourly ratings


    Fully Tested and Approved
    When used in conjunction with Fire Barrier Cast-In Devices in listed systems, 3M™ Fire Barrier Cast-In Device Metal Deck Adaptors are firestop tested up to 3 hours in accordance with ASTM E 814 (UL 1479).

    The Science of Better Fire Protection from 3M
    Since 1925 when one of our lab assistants invented masking tape, 3M has been applying science to life –developing adhesive products and technologies that help entire industries and individual businesses worldwide. The work that began with a single 3M engineer now spans decades and generations. And all of it goes into each of our adhesives, sealants, protective coatings, devices and capability-expanding adaptors including 3M™ Fire Barrier Cast-In Device Metal Deck Adaptors to improve performance, and to help businesses like yours operate faster, better and more efficiently.